Skip to content
An example of work by Wentworth Ag USA

Quiet Dryer

The Quiet Dryer features a best-in-class, commercial-grade blower, the same type used in Zimmerman tower dryers. It is 50% quieter than vane axial portable dryers, producing a more comfortable, less harsh tone. The dryer offers versatile operation with the option to heat or dry/cool, and it is compatible with both LP and natural gas. It can be powered by either 1-phase or 3-phase electrical systems, and stacked models are also available.

An example of work by Wentworth Ag USA
GSI Connect

Know Your Dryer a Little Less Personally This Harvest

Harvest is hectic, and the last thing you need is an extra trip to the dryer. With GSI Connect, you know your dryer is doing its job, so you can stay where you are and keep doing yours.

  • 1Control from anywhere
  • 2See your dryer's status, moisture, temperature
  • 3Adjust set points, stop your dryer and change unload speeds
  • 4Monitor your dryer's performance and get alerts to reduce runtime and maximize profit

Product Lineup Overview

Every series at a glance. Full model by model tables for each series follow below.
SeriesMax. Holding Capacity (bu.)Approx. Drying CapacityConfigurationOptional Inverters AvailableModels Available in X-Stream
1100219 - 708420 – 1,160 BPHSingle module, single fan/heaterYes (no dry cool batch)None
1200381 - 708680 – 1,180 BPHSingle module, two fans/heatersN/ANone
1200S&H381 - 708990 – 1,330 BPHSingle module, two fans/heatersYes1220HX, 1222HX, 1226HX
2300731 - 1,3041,460 – 2,700 BPHTwo modules, three fans/heatersYes2320X, 2322X, 2326X
24001,044 - 1,3402,010 – 2,700 BPHTwo modules, four fans/heatersYes2420X, 2426X
34001,074 - 1,9952,190 – 4,000 BPHThree modules, four fans/heatersYes3420X, 3422X, 3426X
36001,534 - 1,9952,950 – 4,000 BPHThree modules, six fans/heatersYes3620X, 3626X

1100 Series

Configuration: single module, single fan and heater with a single plenum. Not expandable. Built for small to medium sized farms using bins of 50,000 bushels or less with adequate bin cooling air.

A good first high speed dryer, delivering 420 to 1,160 BPH All Heat drying at 5-point removal. Primarily an All Heat corn dryer, it can also run Continuous Batch Dry & Cool full time or for specific situations, such as putting a dry cone in a flat bottom wet bin or occasional soybean or wheat drying, and still deliver cooled grain.
Model11081112111411161118112011221126
Dry & Cool 25% to 15% Staged Batch170 BPH210 BPH250 BPH280 BPH320 BPH360 BPH390 BPH460 BPH
Dry & Cool 20% to 15% Staged Batch220 BPH270 BPH320 BPH370 BPH430 BPH480 BPH520 BPH610 BPH
Full Heat 30% to 15%1190 BPH250 BPH300 BPH320 BPH380 BPH410 BPH460 BPH540 BPH
Full Heat 25% to 15%1260 BPH340 BPH390 BPH440 BPH510 BPH560 BPH610 BPH720 BPH
Full Heat 20% to 15%1420 BPH530 BPH610 BPH710 BPH820 BPH910 BPH990 BPH1,160 BPH
Basic Construction1 Module, 1 Stage1 Module, 1 Stage1 Module, 1 Stage1 Module, 1 Stage1 Module, 1 Stage1 Module, 1 Stage1 Module, 1 Stage1 Module, 1 Stage
Grain Columns14″ x 8′ Long14″ x 12′ Long14″ x 14′ Long14″ x 16′ Long14″ x 18′ Long14″ x 20′ Long14″ x 22′ Long14″ x 26′ Long
Total Holding Capacity219 BU327 BU381 BU436 BU490 BU544 BU599 BU708 BU
Grain Column Holding Cap.190 BU282 BU329 BU376 BU423 BU470 BU517 BU611 BU
Top Auger (Loading)8″ Flight / 2 HP8″ Flight / 2 HP8″ Flight / 3 HP8″ Flight / 5 HP8″ Flight / 5 HP8″ Flight / 7.5 HP8″ Flight / 7.5 HP8″ Flight / 10 HP
Capacity3,800 BPH3,800 BPH3,800 BPH3,800 BPH3,800 BPH3,800 BPH3,800 BPH3,800 BPH
Bottom Auger (Unloading)8″ Flight / 10″ Tube – 2.5 HP8″ Flight / 10″ Tube – 2.5 HP8″ Flight / 10″ Tube – 3 HP8″ Flight / 10″ Tube – 5 HP8″ Flight / 10″ Tube – 5 HP8″ Flight / 10″ Tube – 7.5 HP8″ Flight / 10″ Tube – 7.5 HP8″ Flight / 10″ Tube – 10 HP
Meter Roll DriveVFD, 1 HPVFD, 1 HPVFD, 1 HPVFD, 1 HPVFD, 1 HPVFD, 1 HPVFD, 1 HPVFD, 1 HP
Maximum Capacity1,125 BPH1,680 BPH1,960 BPH2,240 BPH2,520 BPH2,800 BPH3,080 BPH3,640 BPH
Transport Length (Hitch to Discharge Auger)17’2″21’2″23’2″25’2″27’2″29’2″31’2″35’2″
Transport Width8′8′8′8′8′8′8′8′
Transport Height213’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)
Approx. Transport Weight5,200 lb.6,300 lb.7,000 lb.7,500 lb.8,000 lb.8,700 lb.9,500 lb.11,000 lb.
Installed Length15’2″19’2″21’2″23’2″25’2″27’2″29’2″33’2″
Installed Width8′8′8′8′8′8′8′8′
Installed Height (Excluding Foundation Supports)14’6″14’6″14’6″14’6″14’6″14’6″14’6″14’6″
Heater (Max BTU)4.5 Mil. btu/hr4.5 Mil. btu/hr5.75 Mil. btu/hr5.75 Mil. btu/hr6.75 Mil. btu/hr7.5 Mil. btu/hr8.75 Mil. btu/hr10.25 Mil. btu/hr
Fan 1 PH10-16 HP, 36″10-16 HP, 36″10-16 HP, 40″10-16 HP, 40″N/AN/AN/AN/A
Fan 3 PH10-16 HP, 36″15 HP, 36″15 HP, 40″15 HP, 40″20 HP, 42″25 HP, 42″30 HP, 42″40 HP, 42″
Single Phase, 230 V. (Min/Max Amps)5101/122101/156109/164124/179N/AN/AN/AN/A
Three Phase, 208 V. (Min/Max Amps)557/9557/9564/11577/12788/138117/193128/204167/244
Three Phase, 230 V. (Min/Max Amps)553/8353/8860/10871/12081/130107/178117/188157/228
Three Phase, 460 V. (Min/Max Amps)529/4129/4432/5438/6043/6556/8961/9481/114
Three Phase, 575 V. (Min/Max Amps)525/3625/3628/4533/5036/5446/7350/7767/94

1200 Series

Configuration: single module with 2 vane axial fans and heaters, each with its own plenum in a 67/33 split. Not expandable. For small to medium sized farms that need flexibility in drying options.

Good for corn and many other grains in Dry & Cool mode, and for corn or rice in All Heat. Its economical design gives 400 to 730 BPH Dry & Cool and 680 to 1,160 BPH All Heat at 5-point removal. Like all Vision-equipped, multiple fan GSI dryers, it runs in any mode: All Heat, Dry & Cool, Continuous Flow or Batch.
Model121412161218122012221226
Dry & Cool 25% to 15%250 BPH290 BPH320 BPH350 BPH400 BPH450 BPH
Dry & Cool 20% to 15%400 BPH470 BPH510 BPH560 BPH640 BPH730 BPH
Full Heat 30% to 15%1330 BPH380 BPH410 BPH430 BPH480 BPH540 BPH
Full Heat 25% to 15%1420 BPH480 BPH520 BPH590 BPH650 BPH730 BPH
Full Heat 20% to 15%1680 BPH770 BPH840 BPH950 BPH1,060 BPH1,180 BPH
Basic Construction1 Module / 2 Stages1 Module / 2 Stages1 Module / 2 Stages1 Module / 2 Stages1 Module / 2 Stages1 Module / 2 Stages
Grain Columns14″ x 14′ Long14″ x 16′ Long14″ x 18′ Long14″ x 20′ Long14″ x 22′ Long14″ x 26′ Long
Total Holding Capacity381 BU436 BU490 BU544 BU599 BU708 BU
Grain Column Holding Cap.329 BU376 BU423 BU470 BU517 BU611 BU
Top Auger (Loading)8″ 5 HP8″ 5 HP8″ 5 HP8″ 7.5 HP8″ 7.5 HP8″ 10 HP
Capacity3,800 BPH3,800 BPH3,800 BPH3,800 BPH3,800 BPH3,800 BPH
Bottom Auger (Unloading)8″ Flight / 10″ Tube – 5 HP8″ Flight / 10″ Tube – 5 HP8″ Flight / 10″ Tube – 5 HP8″ Flight / 10″ Tube – 7.5 HP8″ Flight / 10″ Tube – 7.5 HP8″ Flight / 10″ Tube – 10 HP
Meter Roll DriveVFD, 1 HPVFD, 1 HPVFD, 1 HPVFD, 1 HPVFD, 1 HPVFD, 1 HP
Maximum Capacity1,960 BPH2,240 BPH2,520 BPH2,800 BPH3,080 BPH3,640 BPH
Transport Length (Hitch to Discharge Auger)23’2″25’2″27’2″29’2″31’2″35’2″
Transport Width8′8′8′8′8′8′
Transport Height213’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)
Approx. Transport Weight7,600 lbs.8,200 lbs.9,000 lbs.9,800 lbs.10,500 lbs.12,000 lbs.
Installed Length21’2″23’2″25’2″27’2″29’2″33’2″
Installed Width8′8′8′8′8′8′
Installed Height (Excluding Foundation Supports)14’6″14’6″14’6″14’6″14’6″14’6″
Top Heater (Max BTU)1@3.5 Mil. btu/hr1@4.5 Mil. btu/hr1@4.5 Mil. btu/hr1@5.5 Mil. btu/hr1@6.75 Mil. btu/hr1@7.5 Mil. btu/hr
Bottom Heater (Max BTU)1@3 Mil. btu/hr1@3 Mil. btu/hr1@3 Mil. btu/hr1@3.0 Mil. btu/hr1@3.0 Mil. btu/hr1@3.0 Mil. btu/hr
Top Fan 1 PH1@12 HP, 36″1@15 HP, 36″1@15 HP, 36″1@15 HP, 40″N/AN/A
Bottom Fan 1 PH1@12 HP, 28″1@10 HP, 28″1@10 HP, 28″1@10 HP, 28″N/AN/A
Top Fan 3 PH1@12 HP, 36″1@15 HP, 36″1@15 HP, 36″1@15 HP, 40″1@20 HP, 42″1@25 HP, 42″
Bottom Fan 3 PH1@12 HP, 28″1@10 HP, 28″1@10 HP, 28″1@12 HP, 28″1@12 HP, 28″1@12 HP, 28″
Single Phase, 230 V. (Min/Max Amps)3157/212177/232177/232191/246N/AN/A
Three Phase, 208 V. (Min/Max Amps)3112/162112/162112/162125/202136/213164/240
Three Phase, 230 V. (Min/Max Amps)399/148104/153104/153116/187126/197154/225
Three Phase, 460 V. (Min/Max Amps)352/7455/7655/7661/9366/9880/112
Three Phase, 575 V. (Min/Max Amps)348/6649/6649/6654/8157/8468/95

1200S&H Series

Configuration: single module with two vane axial fans and heaters, each with its own plenum in a 50/50 split. S-Series dryers are upgradable with additional modules; the H-Series is not. As the base for a two or three stack dryer, the 1200S suits small, medium or large farms with definite plans to add a second or third module later.

On its own, the 1200S, like the 1200H, suits farms that need maximum capacity on single phase and/or mainly run All Heat or can use Staged Auto for Dry & Cool. The 1200H is mainly Staged Auto or Batch Dry & Cool for corn and many other grains, and runs corn or rice in All Heat: 570 to 700 BPH Dry & Cool and 1,080 to 1,330 BPH All Heat at 5-point removal.
Model1214S1218S1220S/1220H †1222S/1222H †1226S/1226H †
Dry & Cool 25% to 15% Staged Batch260 BPH350 BPH400 BPH430 BPH530 BPH
Dry & Cool 20% to 15% Staged Batch360 BPH450 BPH520 BPH570 BPH700 BPH
Dry and Cool 25% to 15%185 BPH240 BPH280 BPH300 BPH375 BPH
Dry and Cool 20% to 15%300 BPH385 BPH445 BPH485 BPH600 BPH
Full Heat 30% to 15%1300 BPH390 BPH450 BPH490 BPH620 BPH
Full Heat 25% to 15%1450 BPH540 BPH620 BPH670 BPH820 BPH
Full Heat 20% to 15%1730 BPH860 BPH990 BPH1,080 BPH1,330 BPH
Basic Construction1 Module / 2 Stages1 Module / 2 Stages1 Module / 2 Stages1 Module / 2 Stages1 Module / 2 Stages
Grain Columns14″ x 14′ Long14″ x 18′ Long14″ x 20′ Long14″ x 22′ Long14″ x 26′ Long
Total Holding Capacity381 BU490 BU544 BU599 BU708 BU
Grain Column Holding Cap.329 BU423 BU470 BU517 BU611 BU
Top Auger (Loading)5 HP5 HP7.5 HP7.5 HP10 HP
Capacity3,800 BPH3,800 BPH3,800 BPH3,800 BPH3,800 BPH
Bottom Auger (Unloading)8″ Flight / 10″ Tube / 5 HP8″ Flight / 10″ Tube / 5 HP8″ Flight / 10″ Tube / 7.5 HP8″ Flight / 10″ Tube / 7.5 HP8″ Flight / 10″ Tube / 10 HP
Meter Roll DriveVFD, 1 HPVFD, 1 HPVFD, 1 HPVFD, 1 HPVFD, 1 HP
Maximum Capacity1,960 BPH2,520 BPH2,800 BPH3,080 BPH3,640 BPH
Transport Length (Hitch to Discharge Auger)23’2″27’2″29’2″31’2″35’2″
Transport Width8′8′8′8′8′
Transport Height213’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)
Approx. Transport Weight9,500 lbs.11,500 lbs.14,500 lbs.15,500 lbs.18,500 lbs.
Installed Length21’2″25’2″27’2″30’2″33’2″
Installed Width8’8″8’8″8’8″ / 8′8’8″ / 8′8’8″ / 8′
Installed Height (Excluding Foundation Supports)14’6″14’6″14’6″14’6″14’6″
Heaters (Max BTU)2@3.0 Mil.btu/hr2@3.5 Mil.btu/hr2@4.5 Mil.btu/hr2@4.5 Mil.btu/hr2@6.75 Mil.btu/hr
Fans 1 PH2@12 HP, 28″2@10-12 HP, 36″2@15 HP, 36″2@15 HP, 36″N/A
Fans 3 PH2@12 HP, 28″2@10-12 HP, 36″2@15 HP, 36″2@15 HP, 36″2@25 HP, 40″
Single Phase, 230 V. (Min/Max Amps)3157/212157/212211/266211/266N/A
Three Phase, 208 V. (Min/Max Amps)3106/156106/144131/208131/208196/273
Three Phase, 230 V. (Min/Max Amps)399/14899/134121/192121/192183/254
Three Phase, 460 V. (Min/Max Amps)352/7452/6863/9663/9694/127
Three Phase, 575 V. (Min/Max Amps)348/6648/6654/8154/8177/104

2300 & 2400 Series

2300 Series: two modules, three fans and heaters, one on the upper module and two on the lower module. 2400 Series: two modules, four fans and heaters, two on the upper module and two on the lower. For medium to large farms that want more drying capacity without a bigger footprint.

Primarily continuous Dry & Cool for corn and many other grains, or All Heat for corn or rice: 1,000 to 1,840 BPH Dry & Cool and 1,460 to 2,700 BPH All Heat high speed drying at 5-point removal. Note: cooling corn dried in All Heat mode safely, without special management, takes bins no larger than 50,000 bu. at no more than 1,500 BPH capacity.
Models2314231823202322232624202426
Dry & Cool 25% to 15%620 BPH770 BPH850 BPH930 BPH1,130 BPH850 BPH1,130 BPH
Dry & Cool 20% to 15%1,000 BPH1,240 BPH1,380 BPH1,500 BPH1,840 BPH1,380 BPH1,840 BPH
Full Heat 30% to 15%1670 BPH830 BPH920 BPH1,010 BPH1,200 BPH920 BPH1,200 BPH
Full Heat 25% to 15%1900 BPH1,120 BPH1,250 BPH1,360 BPH1,670 BPH1,250 BPH1,670 BPH
Full Heat 20% to 15%11,460 BPH1,810 BPH2,010 BPH2,200 BPH2,700 BPH2,010 BPH2,700 BPH
Basic Construction2 Modules/3 Stages2 Modules/3 Stages2 Modules/3 Stages2 Modules/3 Stages2 Modules/3 Stages2 Modules/4 Stages2 Modules/4 Stages
Grain Columns14″ x 14′ Long14″ x 18′ Long14″ x 20′ Long14″ x 22′ Long14″ x 26′ Long14″ x 20′ Long14″ x 26′ Long
Total Holding Capacity731 BU940 BU1,044 BU1,149 BU1,304 BU1,044 BU1,340 BU
Grain Column Holding Cap.679 BU873 BU970 BU1,067 BU1,261 BU970 BU1,261 BU
Top Auger (Loading)5 HP5 HP7.5 HP7.5 HP10 HP7.5 HP10 HP
Capacity3,800 BPH3,800 BPH3,800 BPH3,800 BPH3,800 BPH3,800 BPH3,800 BPH
Bottom Auger (Unloading)8″ Flight / 10″ Tube – 5 HP8″ Flight / 10″ Tube – 5 HP8″ Flight / 10″ Tube – 7.5 HP8″ Flight / 10″ Tube – 7.5 HP8″ Flight / 10″ Tube – 10 HP8″ Flight / 10″ Tube – 7.5 HP8″ Flight / 10″ Tube – 10 HP
Meter Roll DriveVFD, 1 HPVFD, 1 HPVFD, 1 HPVFD, 1 HPVFD, 1 HPVFD, 1 HPVFD, 1 HP
Maximum Capacity1,960 BPH2,520 BPH2,800 BPH3,080 BPH3,640 BPH2,800 BPH3,640 BPH
Transport Length (Hitch to Discharge Auger)23’2″27’2″29’2″31’2″35’2″29’2″35’2″
Transport Width8′8′8′8′8′8′8′
Transport Height213’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)
Approx. Transport Weight (Less Transport Kit)16,000 lbs.19,000 lbs.21,000 lbs.22,500 lbs.25,000 lbs.23,500 lbs.28,000 lbs.
Installed Length23’10”27’10”29’10”31’10”35’10”29’10”35’10”
Installed Width8’8″8’8″8’8″8’8″8’8″8’8″8’8″
Installed Height (Excluding Foundation Supports)25’11”25’11”25’11”25’11”25’11”25’11”25’11”
Top Heaters (Max BTU)1@5.5 Mil. btu/hr1@6.75 Mil. btu/hr1@7.5 Mil. btu/hr1@8.75 Mil. btu/hr1@10.25 Mil. btu/hr2@4.5 Mil. btu/hr2@6.75 Mil. btu/hr
Bottom Heaters (Max BTU)2@3.0 Mil. btu/hr2@3.5 Mil. btu/hr2@4.5 Mil. btu/hr2@4.5 Mil. btu/hr2@6.75 Mil. btu/hr2@4.5 Mil. btu/hr2@6.75 Mil. btu/hr
Top Fans 1 PH1@15 HP, 40″N/AN/AN/AN/AN/AN/A
Bottom Fans 1 PH2@10-12 HP, 28″N/AN/AN/AN/AN/AN/A
Top Fans 3 PH1@15 HP, 40″1@20 HP, 42″1@25 HP, 42″1@30 HP, 42″1@40 HP, 42″2@15 HP, 36″2@25 HP, 40″
Bottom Fans 3 PH2@10-12 HP, 28″2@10-12 HP, 36″2@15 HP, 36″2@15 HP, 36″2@25 HP, 40″2@15 HP, 36″2@25 HP, 40″
Single Phase, 220 V. (Min/Max Amps)3230/285N/AN/AN/AN/A359/421N/A
Three Phase, 208 V. (Min/Max Amps)3147/197158/208199/275199/275302/379213/295382/464
Three Phase, 230 V. (Min/Max Amps)3137/186135/184183/254183/254281/352197/273313/389
Three Phase, 460 V. (Min/Max Amps)371/9370/9294/12799/132143/176101/139159/197
Three Phase, 575 V. (Min/Max Amps)365/8268/8678/10582/109115/14285/117128/160

3400 & 3600 Series

3400 Series: three modules, four fans and heaters, one on the upper and middle modules and two on the lower module. 3600 Series: three modules, six fans and heaters, two on each module. The maximum grain drying capacity in a Portable Dryer, for large farm operations.

Primarily continuous Dry & Cool for corn and many other grains, or All Heat for corn or rice: 840 to 2,450 BPH Dry & Cool and 1,000 to 4,000 BPH All Heat high speed drying at 5-point removal. Note: cooling corn dried in All Heat mode safely, without special management, takes bins no larger than 50,000 bu. at no more than 1,500 BPH capacity.
Model3414341834203422342636203626
Dry & Cool 25% to 15%840 BPH1,040 BPH1,120 BPH1,250 BPH1,520 BPH1,120 BPH1,520 BPH
Dry & Cool 20% to 15%1,340 BPH1,670 BPH1,800 BPH2,020 BPH2,450 BPH1,800 BPH2,450 BPH
Full Heat 30% to 15%11,000 BPH1,250 BPH1,400 BPH1,510 BPH1,820 BPH1,400 BPH1,820 BPH
Full Heat 25% to 15%11,360 BPH1,680 BPH1,830 BPH2,040 BPH2,480 BPH1,830 BPH2,480 BPH
Full Heat 20% to 15%12,190 BPH2,720 BPH2,950 BPH63,300 BPH64,000 BPH62,950 BPH4,000 BPH
Basic Construction3 Modules/4 Stages3 Modules/4 Stages3 Modules/4 Stages3 Modules/4 Stages3 Modules/4 Stages3 Modules/6 Stages3 Modules/6 Stages
Grain Columns14″ x 14′ Long14″ x 18′ Long14″ x 20′ Long14″ x 22′ Long14″ x 26′ Long14″ x 20′ Long14″ x 26′ Long
Total Holding Capacity1,074 BU1,381 BU1,534 BU1,688 BU1,995 BU1,534 BU1,995 BU
Grain Column Holding Cap.1,022 BU1,314 BU1,460 BU1,606 BU1,898 BU1,460 BU1,898 BU
Top Auger (Loading)5 HP5 HP7.5 HP7.5 HP10 HP7.5 HP10 HP
Capacity3,800 BPH3,800 BPH3,800 BPH3,800 BPH3,800 BPH3,800 BPH3,800 BPH
Bottom Auger (Unloading)8″ Flight / 10″ Tube – 5 HP8″ Flight / 10″ Tube – 5 HP8″ Flight / 10″ Tube – 7.5 HP8″ Flight / 10″ Tube – 7.5 HP8″ Flight / 10″ Tube – 10 HP8″ Flight/10″ Tube – 7.5 HP8″ Flight/10″ Tube – 10 HP
Meter Roll DriveVFD, 1 HPVFD, 1 HPVFD, 1 HPVFD, 1 HPVFD, 1 HPVFD, 1 HPVFD, 1 HP
Maximum Capacity1,960 BPH2,520 BPH2,800 BPH3,080 BPH3,640 BPH2,800 BPH3,640 BPH
Transport Length (Hitch to Discharge Auger)23’2″27’2″29’2″31’2″35’2″29’2″35’2″
Transport Width8′8′8′8′8′8′8′
Transport Height213’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)13’5″ (11’9″)
Approx. Transport Weight (Less Transport Kit)23,000 lbs.26,500 lbs.29,500 lbs.30,500 lbs.35,000 lbs.30,170 lbs.38,750 lbs.
Installed Length23’10”27’10”29’10”31’10”35’10”29’10”35’10”
Installed Width8’8″8’8″8’8″8’8″8’8″8’8″8’8″
Installed Height (Excluding Foundation Supports)37’3″37’3″37’3″37’3″37’3″37’3″37’3″
Top Heaters (Max BTU)2@5.5 Mil. btu/hr2@6.75 Mil. btu/hr2@7.5 Mil. btu/hr2@8.75 Mil. btu/hr2@10.25 Mil. btu/hr3@4.5 Mil. btu/hr3@6.75 Mil. btu/hr
Bottom Heaters (Max BTU)2@3 Mil. btu/hr2@3.5 Mil. btu/hr2@4.5 Mil. btu/hr2@4.5 Mil. btu/hr2@6.75 Mil. btu/hr3@4.5 Mil. btu/hr3@6.75 Mil. btu/hr
Top Fans 1 PH2@15 HP, 40″N/AN/AN/AN/AN/AN/A
Bottom Fans 1 PH2@12 HP, 28″N/AN/AN/AN/AN/AN/A
Top Fans 3 PH2@15 HP, 40″2@20 HP, 42″2@25 HP, 42″2@30 HP, 42″2@40 HP, 42″3@15 HP, 36″3@25 HP, 40″
Bottom Fans 3 PH2@12 HP, 28″2@10-12 HP, 36″2@15 HP, 36″2@15 HP, 36″2@25 HP, 40″3@15 HP, 36″3@25 HP, 40″
Single Phase, 230 V. (Min/Max Amps)3303/358N/AN/AN/AN/AN/AN/A
Three Phase, 208 V. (Min/Max Amps)3188/238210/260266/343266/343300/377295/377539/620
Three Phase, 230 V. (Min/Max Amps)3175/224183/232245/316245/316279/350273/349441/517
Three Phase, 460 V. (Min/Max Amps)390/11294/116125/158135/168192/225139/177223/261
Three Phase, 575 V. (Min/Max Amps)381/9888/106103/130111/138154/181117/149179/211

X-Stream Series

Configuration: various. X-Stream is an optional rearrangement of the fans on 1200H, 1200S, 2300, 2400, 3400 or 3600 Series dryers, for any size farm that wants to dry grain more evenly.

X-Stream evens out heat delivery from the front to the back of the dryer, improving quality and efficiency. These dryers keep all the features, benefits and best use criteria of their parent series.
Models1220SX & 1220HX †1222SX & 1222HX †1226SX & 1226HX †2320X2322X2326X2420X2426X3420X3422X3426X3620X3626X
Modules1112222233333
Fans2223334444466
Phase1 or 31 or 333331 or 333331 or 33
VoltageALLALLALLALLALLALLALLALLALLALLALLALLALL
FuelLP or NGLP or NGLP or NGLP or NGLP or NGLP or NGLP or NGLP or NGLP or NGLP or NGLP or NGLP or NGLP or NG
Weight (lbs.)14,50015,50018,50021,00022,50025,00024,10028,60029,50030,50035,00031,00039,600
Full Heat (BPH) 10 pt. 25-15%6156708201,2451,3551,6701,2501,6701,8252,0402,4751,8302,480
Full Heat (BPH) 5 pt. 20-15%9901,0801,3302,0102,1952,7002,0102,7002,95063,30064,00062,95064,0006
Dry & Cool (BPH) 10 pt. 25-15%2803003758509301,1308501,1301,1201,2501,5201,1201,520
Dry & Cool (BPH) 5 pt. 20-15%4454856001,3751,5001,8351,3801,8401,8002,0152,4451,8002,020

Request a Quote for GSI Portable Dryers