- •Harvest your grain earlier at higher moisture levels and dry it in bins on the farm, increasing yields and improving profits.
- •Shorten wait time during drying, minimize weather risks, reduce dry matter loses, and reduce head shatter loss.
- •Single, double or triple module models available.
- •All heat or Dry/Cool operation. LP or natural gas.
- •Monitor performance and control from anywhere with GSI Connect.
Built to Perform

Vision Controls
Vision controls provide easy operation with a large, color touchscreen display that's simple to read. Positioned on the dryer or remotely with minimal wiring, these controls are specifically designed for GSI grain dryers, offering a wide range of settings and options to give you full control over your drying process.

Static Moisture Sampler
Enhance the accuracy of your moisture samples with the Static Moisture Sampler. This sampler takes readings only when the grain is stationary, not flowing, and is equipped with debris guards to ensure a clean, precise sample free from contaminants.

Quiet Dryer
The Quiet Dryer features a best-in-class, commercial-grade blower, the same type used in Zimmerman tower dryers. It is 50% quieter than vane axial portable dryers, producing a more comfortable, less harsh tone. The dryer offers versatile operation with the option to heat or dry/cool, and it is compatible with both LP and natural gas. It can be powered by either 1-phase or 3-phase electrical systems, and stacked models are also available.

Know Your Dryer a Little Less Personally This Harvest
Harvest is hectic, and the last thing you need is an extra trip to the dryer. With GSI Connect, you know your dryer is doing its job, so you can stay where you are and keep doing yours.
- 1Control from anywhere
- 2See your dryer's status, moisture, temperature
- 3Adjust set points, stop your dryer and change unload speeds
- 4Monitor your dryer's performance and get alerts to reduce runtime and maximize profit
Getting Started is Easy

Work with your GSI dealer to make sure your dryer is connect-ready

Download the app

Pair with dryer
Best of all, portable dryers are just the beginning. GSI is working to make GSI Storage and Material Handling connect-ready too, so with GSI Connect you can put your entire grain system in your hands.
Specifications
Product Lineup Overview
| Series | Max. Holding Capacity (bu.) | Approx. Drying Capacity | Configuration | Optional Inverters Available | Models Available in X-Stream |
|---|---|---|---|---|---|
| 1100 | 219 - 708 | 420 – 1,160 BPH | Single module, single fan/heater | Yes (no dry cool batch) | None |
| 1200 | 381 - 708 | 680 – 1,180 BPH | Single module, two fans/heaters | N/A | None |
| 1200S&H | 381 - 708 | 990 – 1,330 BPH | Single module, two fans/heaters | Yes | 1220HX, 1222HX, 1226HX |
| 2300 | 731 - 1,304 | 1,460 – 2,700 BPH | Two modules, three fans/heaters | Yes | 2320X, 2322X, 2326X |
| 2400 | 1,044 - 1,340 | 2,010 – 2,700 BPH | Two modules, four fans/heaters | Yes | 2420X, 2426X |
| 3400 | 1,074 - 1,995 | 2,190 – 4,000 BPH | Three modules, four fans/heaters | Yes | 3420X, 3422X, 3426X |
| 3600 | 1,534 - 1,995 | 2,950 – 4,000 BPH | Three modules, six fans/heaters | Yes | 3620X, 3626X |
1100 Series
Configuration: single module, single fan and heater with a single plenum. Not expandable. Built for small to medium sized farms using bins of 50,000 bushels or less with adequate bin cooling air.
| Model | 1108 | 1112 | 1114 | 1116 | 1118 | 1120 | 1122 | 1126 |
|---|---|---|---|---|---|---|---|---|
| Dry & Cool 25% to 15% Staged Batch | 170 BPH | 210 BPH | 250 BPH | 280 BPH | 320 BPH | 360 BPH | 390 BPH | 460 BPH |
| Dry & Cool 20% to 15% Staged Batch | 220 BPH | 270 BPH | 320 BPH | 370 BPH | 430 BPH | 480 BPH | 520 BPH | 610 BPH |
| Full Heat 30% to 15%1 | 190 BPH | 250 BPH | 300 BPH | 320 BPH | 380 BPH | 410 BPH | 460 BPH | 540 BPH |
| Full Heat 25% to 15%1 | 260 BPH | 340 BPH | 390 BPH | 440 BPH | 510 BPH | 560 BPH | 610 BPH | 720 BPH |
| Full Heat 20% to 15%1 | 420 BPH | 530 BPH | 610 BPH | 710 BPH | 820 BPH | 910 BPH | 990 BPH | 1,160 BPH |
| Basic Construction | 1 Module, 1 Stage | 1 Module, 1 Stage | 1 Module, 1 Stage | 1 Module, 1 Stage | 1 Module, 1 Stage | 1 Module, 1 Stage | 1 Module, 1 Stage | 1 Module, 1 Stage |
| Grain Columns | 14″ x 8′ Long | 14″ x 12′ Long | 14″ x 14′ Long | 14″ x 16′ Long | 14″ x 18′ Long | 14″ x 20′ Long | 14″ x 22′ Long | 14″ x 26′ Long |
| Total Holding Capacity | 219 BU | 327 BU | 381 BU | 436 BU | 490 BU | 544 BU | 599 BU | 708 BU |
| Grain Column Holding Cap. | 190 BU | 282 BU | 329 BU | 376 BU | 423 BU | 470 BU | 517 BU | 611 BU |
| Top Auger (Loading) | 8″ Flight / 2 HP | 8″ Flight / 2 HP | 8″ Flight / 3 HP | 8″ Flight / 5 HP | 8″ Flight / 5 HP | 8″ Flight / 7.5 HP | 8″ Flight / 7.5 HP | 8″ Flight / 10 HP |
| Capacity | 3,800 BPH | 3,800 BPH | 3,800 BPH | 3,800 BPH | 3,800 BPH | 3,800 BPH | 3,800 BPH | 3,800 BPH |
| Bottom Auger (Unloading) | 8″ Flight / 10″ Tube – 2.5 HP | 8″ Flight / 10″ Tube – 2.5 HP | 8″ Flight / 10″ Tube – 3 HP | 8″ Flight / 10″ Tube – 5 HP | 8″ Flight / 10″ Tube – 5 HP | 8″ Flight / 10″ Tube – 7.5 HP | 8″ Flight / 10″ Tube – 7.5 HP | 8″ Flight / 10″ Tube – 10 HP |
| Meter Roll Drive | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP |
| Maximum Capacity | 1,125 BPH | 1,680 BPH | 1,960 BPH | 2,240 BPH | 2,520 BPH | 2,800 BPH | 3,080 BPH | 3,640 BPH |
| Transport Length (Hitch to Discharge Auger) | 17’2″ | 21’2″ | 23’2″ | 25’2″ | 27’2″ | 29’2″ | 31’2″ | 35’2″ |
| Transport Width | 8′ | 8′ | 8′ | 8′ | 8′ | 8′ | 8′ | 8′ |
| Transport Height2 | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) |
| Approx. Transport Weight | 5,200 lb. | 6,300 lb. | 7,000 lb. | 7,500 lb. | 8,000 lb. | 8,700 lb. | 9,500 lb. | 11,000 lb. |
| Installed Length | 15’2″ | 19’2″ | 21’2″ | 23’2″ | 25’2″ | 27’2″ | 29’2″ | 33’2″ |
| Installed Width | 8′ | 8′ | 8′ | 8′ | 8′ | 8′ | 8′ | 8′ |
| Installed Height (Excluding Foundation Supports) | 14’6″ | 14’6″ | 14’6″ | 14’6″ | 14’6″ | 14’6″ | 14’6″ | 14’6″ |
| Heater (Max BTU) | 4.5 Mil. btu/hr | 4.5 Mil. btu/hr | 5.75 Mil. btu/hr | 5.75 Mil. btu/hr | 6.75 Mil. btu/hr | 7.5 Mil. btu/hr | 8.75 Mil. btu/hr | 10.25 Mil. btu/hr |
| Fan 1 PH | 10-16 HP, 36″ | 10-16 HP, 36″ | 10-16 HP, 40″ | 10-16 HP, 40″ | N/A | N/A | N/A | N/A |
| Fan 3 PH | 10-16 HP, 36″ | 15 HP, 36″ | 15 HP, 40″ | 15 HP, 40″ | 20 HP, 42″ | 25 HP, 42″ | 30 HP, 42″ | 40 HP, 42″ |
| Single Phase, 230 V. (Min/Max Amps)5 | 101/122 | 101/156 | 109/164 | 124/179 | N/A | N/A | N/A | N/A |
| Three Phase, 208 V. (Min/Max Amps)5 | 57/95 | 57/95 | 64/115 | 77/127 | 88/138 | 117/193 | 128/204 | 167/244 |
| Three Phase, 230 V. (Min/Max Amps)5 | 53/83 | 53/88 | 60/108 | 71/120 | 81/130 | 107/178 | 117/188 | 157/228 |
| Three Phase, 460 V. (Min/Max Amps)5 | 29/41 | 29/44 | 32/54 | 38/60 | 43/65 | 56/89 | 61/94 | 81/114 |
| Three Phase, 575 V. (Min/Max Amps)5 | 25/36 | 25/36 | 28/45 | 33/50 | 36/54 | 46/73 | 50/77 | 67/94 |
1200 Series
Configuration: single module with 2 vane axial fans and heaters, each with its own plenum in a 67/33 split. Not expandable. For small to medium sized farms that need flexibility in drying options.
| Model | 1214 | 1216 | 1218 | 1220 | 1222 | 1226 |
|---|---|---|---|---|---|---|
| Dry & Cool 25% to 15% | 250 BPH | 290 BPH | 320 BPH | 350 BPH | 400 BPH | 450 BPH |
| Dry & Cool 20% to 15% | 400 BPH | 470 BPH | 510 BPH | 560 BPH | 640 BPH | 730 BPH |
| Full Heat 30% to 15%1 | 330 BPH | 380 BPH | 410 BPH | 430 BPH | 480 BPH | 540 BPH |
| Full Heat 25% to 15%1 | 420 BPH | 480 BPH | 520 BPH | 590 BPH | 650 BPH | 730 BPH |
| Full Heat 20% to 15%1 | 680 BPH | 770 BPH | 840 BPH | 950 BPH | 1,060 BPH | 1,180 BPH |
| Basic Construction | 1 Module / 2 Stages | 1 Module / 2 Stages | 1 Module / 2 Stages | 1 Module / 2 Stages | 1 Module / 2 Stages | 1 Module / 2 Stages |
| Grain Columns | 14″ x 14′ Long | 14″ x 16′ Long | 14″ x 18′ Long | 14″ x 20′ Long | 14″ x 22′ Long | 14″ x 26′ Long |
| Total Holding Capacity | 381 BU | 436 BU | 490 BU | 544 BU | 599 BU | 708 BU |
| Grain Column Holding Cap. | 329 BU | 376 BU | 423 BU | 470 BU | 517 BU | 611 BU |
| Top Auger (Loading) | 8″ 5 HP | 8″ 5 HP | 8″ 5 HP | 8″ 7.5 HP | 8″ 7.5 HP | 8″ 10 HP |
| Capacity | 3,800 BPH | 3,800 BPH | 3,800 BPH | 3,800 BPH | 3,800 BPH | 3,800 BPH |
| Bottom Auger (Unloading) | 8″ Flight / 10″ Tube – 5 HP | 8″ Flight / 10″ Tube – 5 HP | 8″ Flight / 10″ Tube – 5 HP | 8″ Flight / 10″ Tube – 7.5 HP | 8″ Flight / 10″ Tube – 7.5 HP | 8″ Flight / 10″ Tube – 10 HP |
| Meter Roll Drive | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP |
| Maximum Capacity | 1,960 BPH | 2,240 BPH | 2,520 BPH | 2,800 BPH | 3,080 BPH | 3,640 BPH |
| Transport Length (Hitch to Discharge Auger) | 23’2″ | 25’2″ | 27’2″ | 29’2″ | 31’2″ | 35’2″ |
| Transport Width | 8′ | 8′ | 8′ | 8′ | 8′ | 8′ |
| Transport Height2 | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) |
| Approx. Transport Weight | 7,600 lbs. | 8,200 lbs. | 9,000 lbs. | 9,800 lbs. | 10,500 lbs. | 12,000 lbs. |
| Installed Length | 21’2″ | 23’2″ | 25’2″ | 27’2″ | 29’2″ | 33’2″ |
| Installed Width | 8′ | 8′ | 8′ | 8′ | 8′ | 8′ |
| Installed Height (Excluding Foundation Supports) | 14’6″ | 14’6″ | 14’6″ | 14’6″ | 14’6″ | 14’6″ |
| Top Heater (Max BTU) | 1@3.5 Mil. btu/hr | 1@4.5 Mil. btu/hr | 1@4.5 Mil. btu/hr | 1@5.5 Mil. btu/hr | 1@6.75 Mil. btu/hr | 1@7.5 Mil. btu/hr |
| Bottom Heater (Max BTU) | 1@3 Mil. btu/hr | 1@3 Mil. btu/hr | 1@3 Mil. btu/hr | 1@3.0 Mil. btu/hr | 1@3.0 Mil. btu/hr | 1@3.0 Mil. btu/hr |
| Top Fan 1 PH | 1@12 HP, 36″ | 1@15 HP, 36″ | 1@15 HP, 36″ | 1@15 HP, 40″ | N/A | N/A |
| Bottom Fan 1 PH | 1@12 HP, 28″ | 1@10 HP, 28″ | 1@10 HP, 28″ | 1@10 HP, 28″ | N/A | N/A |
| Top Fan 3 PH | 1@12 HP, 36″ | 1@15 HP, 36″ | 1@15 HP, 36″ | 1@15 HP, 40″ | 1@20 HP, 42″ | 1@25 HP, 42″ |
| Bottom Fan 3 PH | 1@12 HP, 28″ | 1@10 HP, 28″ | 1@10 HP, 28″ | 1@12 HP, 28″ | 1@12 HP, 28″ | 1@12 HP, 28″ |
| Single Phase, 230 V. (Min/Max Amps)3 | 157/212 | 177/232 | 177/232 | 191/246 | N/A | N/A |
| Three Phase, 208 V. (Min/Max Amps)3 | 112/162 | 112/162 | 112/162 | 125/202 | 136/213 | 164/240 |
| Three Phase, 230 V. (Min/Max Amps)3 | 99/148 | 104/153 | 104/153 | 116/187 | 126/197 | 154/225 |
| Three Phase, 460 V. (Min/Max Amps)3 | 52/74 | 55/76 | 55/76 | 61/93 | 66/98 | 80/112 |
| Three Phase, 575 V. (Min/Max Amps)3 | 48/66 | 49/66 | 49/66 | 54/81 | 57/84 | 68/95 |
1200S&H Series
Configuration: single module with two vane axial fans and heaters, each with its own plenum in a 50/50 split. S-Series dryers are upgradable with additional modules; the H-Series is not. As the base for a two or three stack dryer, the 1200S suits small, medium or large farms with definite plans to add a second or third module later.
| Model | 1214S | 1218S | 1220S/1220H † | 1222S/1222H † | 1226S/1226H † |
|---|---|---|---|---|---|
| Dry & Cool 25% to 15% Staged Batch | 260 BPH | 350 BPH | 400 BPH | 430 BPH | 530 BPH |
| Dry & Cool 20% to 15% Staged Batch | 360 BPH | 450 BPH | 520 BPH | 570 BPH | 700 BPH |
| Dry and Cool 25% to 15% | 185 BPH | 240 BPH | 280 BPH | 300 BPH | 375 BPH |
| Dry and Cool 20% to 15% | 300 BPH | 385 BPH | 445 BPH | 485 BPH | 600 BPH |
| Full Heat 30% to 15%1 | 300 BPH | 390 BPH | 450 BPH | 490 BPH | 620 BPH |
| Full Heat 25% to 15%1 | 450 BPH | 540 BPH | 620 BPH | 670 BPH | 820 BPH |
| Full Heat 20% to 15%1 | 730 BPH | 860 BPH | 990 BPH | 1,080 BPH | 1,330 BPH |
| Basic Construction | 1 Module / 2 Stages | 1 Module / 2 Stages | 1 Module / 2 Stages | 1 Module / 2 Stages | 1 Module / 2 Stages |
| Grain Columns | 14″ x 14′ Long | 14″ x 18′ Long | 14″ x 20′ Long | 14″ x 22′ Long | 14″ x 26′ Long |
| Total Holding Capacity | 381 BU | 490 BU | 544 BU | 599 BU | 708 BU |
| Grain Column Holding Cap. | 329 BU | 423 BU | 470 BU | 517 BU | 611 BU |
| Top Auger (Loading) | 5 HP | 5 HP | 7.5 HP | 7.5 HP | 10 HP |
| Capacity | 3,800 BPH | 3,800 BPH | 3,800 BPH | 3,800 BPH | 3,800 BPH |
| Bottom Auger (Unloading) | 8″ Flight / 10″ Tube / 5 HP | 8″ Flight / 10″ Tube / 5 HP | 8″ Flight / 10″ Tube / 7.5 HP | 8″ Flight / 10″ Tube / 7.5 HP | 8″ Flight / 10″ Tube / 10 HP |
| Meter Roll Drive | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP |
| Maximum Capacity | 1,960 BPH | 2,520 BPH | 2,800 BPH | 3,080 BPH | 3,640 BPH |
| Transport Length (Hitch to Discharge Auger) | 23’2″ | 27’2″ | 29’2″ | 31’2″ | 35’2″ |
| Transport Width | 8′ | 8′ | 8′ | 8′ | 8′ |
| Transport Height2 | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) |
| Approx. Transport Weight | 9,500 lbs. | 11,500 lbs. | 14,500 lbs. | 15,500 lbs. | 18,500 lbs. |
| Installed Length | 21’2″ | 25’2″ | 27’2″ | 30’2″ | 33’2″ |
| Installed Width | 8’8″ | 8’8″ | 8’8″ / 8′ | 8’8″ / 8′ | 8’8″ / 8′ |
| Installed Height (Excluding Foundation Supports) | 14’6″ | 14’6″ | 14’6″ | 14’6″ | 14’6″ |
| Heaters (Max BTU) | 2@3.0 Mil.btu/hr | 2@3.5 Mil.btu/hr | 2@4.5 Mil.btu/hr | 2@4.5 Mil.btu/hr | 2@6.75 Mil.btu/hr |
| Fans 1 PH | 2@12 HP, 28″ | 2@10-12 HP, 36″ | 2@15 HP, 36″ | 2@15 HP, 36″ | N/A |
| Fans 3 PH | 2@12 HP, 28″ | 2@10-12 HP, 36″ | 2@15 HP, 36″ | 2@15 HP, 36″ | 2@25 HP, 40″ |
| Single Phase, 230 V. (Min/Max Amps)3 | 157/212 | 157/212 | 211/266 | 211/266 | N/A |
| Three Phase, 208 V. (Min/Max Amps)3 | 106/156 | 106/144 | 131/208 | 131/208 | 196/273 |
| Three Phase, 230 V. (Min/Max Amps)3 | 99/148 | 99/134 | 121/192 | 121/192 | 183/254 |
| Three Phase, 460 V. (Min/Max Amps)3 | 52/74 | 52/68 | 63/96 | 63/96 | 94/127 |
| Three Phase, 575 V. (Min/Max Amps)3 | 48/66 | 48/66 | 54/81 | 54/81 | 77/104 |
2300 & 2400 Series
2300 Series: two modules, three fans and heaters, one on the upper module and two on the lower module. 2400 Series: two modules, four fans and heaters, two on the upper module and two on the lower. For medium to large farms that want more drying capacity without a bigger footprint.
| Models | 2314 | 2318 | 2320 | 2322 | 2326 | 2420 | 2426 |
|---|---|---|---|---|---|---|---|
| Dry & Cool 25% to 15% | 620 BPH | 770 BPH | 850 BPH | 930 BPH | 1,130 BPH | 850 BPH | 1,130 BPH |
| Dry & Cool 20% to 15% | 1,000 BPH | 1,240 BPH | 1,380 BPH | 1,500 BPH | 1,840 BPH | 1,380 BPH | 1,840 BPH |
| Full Heat 30% to 15%1 | 670 BPH | 830 BPH | 920 BPH | 1,010 BPH | 1,200 BPH | 920 BPH | 1,200 BPH |
| Full Heat 25% to 15%1 | 900 BPH | 1,120 BPH | 1,250 BPH | 1,360 BPH | 1,670 BPH | 1,250 BPH | 1,670 BPH |
| Full Heat 20% to 15%1 | 1,460 BPH | 1,810 BPH | 2,010 BPH | 2,200 BPH | 2,700 BPH | 2,010 BPH | 2,700 BPH |
| Basic Construction | 2 Modules/3 Stages | 2 Modules/3 Stages | 2 Modules/3 Stages | 2 Modules/3 Stages | 2 Modules/3 Stages | 2 Modules/4 Stages | 2 Modules/4 Stages |
| Grain Columns | 14″ x 14′ Long | 14″ x 18′ Long | 14″ x 20′ Long | 14″ x 22′ Long | 14″ x 26′ Long | 14″ x 20′ Long | 14″ x 26′ Long |
| Total Holding Capacity | 731 BU | 940 BU | 1,044 BU | 1,149 BU | 1,304 BU | 1,044 BU | 1,340 BU |
| Grain Column Holding Cap. | 679 BU | 873 BU | 970 BU | 1,067 BU | 1,261 BU | 970 BU | 1,261 BU |
| Top Auger (Loading) | 5 HP | 5 HP | 7.5 HP | 7.5 HP | 10 HP | 7.5 HP | 10 HP |
| Capacity | 3,800 BPH | 3,800 BPH | 3,800 BPH | 3,800 BPH | 3,800 BPH | 3,800 BPH | 3,800 BPH |
| Bottom Auger (Unloading) | 8″ Flight / 10″ Tube – 5 HP | 8″ Flight / 10″ Tube – 5 HP | 8″ Flight / 10″ Tube – 7.5 HP | 8″ Flight / 10″ Tube – 7.5 HP | 8″ Flight / 10″ Tube – 10 HP | 8″ Flight / 10″ Tube – 7.5 HP | 8″ Flight / 10″ Tube – 10 HP |
| Meter Roll Drive | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP |
| Maximum Capacity | 1,960 BPH | 2,520 BPH | 2,800 BPH | 3,080 BPH | 3,640 BPH | 2,800 BPH | 3,640 BPH |
| Transport Length (Hitch to Discharge Auger) | 23’2″ | 27’2″ | 29’2″ | 31’2″ | 35’2″ | 29’2″ | 35’2″ |
| Transport Width | 8′ | 8′ | 8′ | 8′ | 8′ | 8′ | 8′ |
| Transport Height2 | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) |
| Approx. Transport Weight (Less Transport Kit) | 16,000 lbs. | 19,000 lbs. | 21,000 lbs. | 22,500 lbs. | 25,000 lbs. | 23,500 lbs. | 28,000 lbs. |
| Installed Length | 23’10” | 27’10” | 29’10” | 31’10” | 35’10” | 29’10” | 35’10” |
| Installed Width | 8’8″ | 8’8″ | 8’8″ | 8’8″ | 8’8″ | 8’8″ | 8’8″ |
| Installed Height (Excluding Foundation Supports) | 25’11” | 25’11” | 25’11” | 25’11” | 25’11” | 25’11” | 25’11” |
| Top Heaters (Max BTU) | 1@5.5 Mil. btu/hr | 1@6.75 Mil. btu/hr | 1@7.5 Mil. btu/hr | 1@8.75 Mil. btu/hr | 1@10.25 Mil. btu/hr | 2@4.5 Mil. btu/hr | 2@6.75 Mil. btu/hr |
| Bottom Heaters (Max BTU) | 2@3.0 Mil. btu/hr | 2@3.5 Mil. btu/hr | 2@4.5 Mil. btu/hr | 2@4.5 Mil. btu/hr | 2@6.75 Mil. btu/hr | 2@4.5 Mil. btu/hr | 2@6.75 Mil. btu/hr |
| Top Fans 1 PH | 1@15 HP, 40″ | N/A | N/A | N/A | N/A | N/A | N/A |
| Bottom Fans 1 PH | 2@10-12 HP, 28″ | N/A | N/A | N/A | N/A | N/A | N/A |
| Top Fans 3 PH | 1@15 HP, 40″ | 1@20 HP, 42″ | 1@25 HP, 42″ | 1@30 HP, 42″ | 1@40 HP, 42″ | 2@15 HP, 36″ | 2@25 HP, 40″ |
| Bottom Fans 3 PH | 2@10-12 HP, 28″ | 2@10-12 HP, 36″ | 2@15 HP, 36″ | 2@15 HP, 36″ | 2@25 HP, 40″ | 2@15 HP, 36″ | 2@25 HP, 40″ |
| Single Phase, 220 V. (Min/Max Amps)3 | 230/285 | N/A | N/A | N/A | N/A | 359/421 | N/A |
| Three Phase, 208 V. (Min/Max Amps)3 | 147/197 | 158/208 | 199/275 | 199/275 | 302/379 | 213/295 | 382/464 |
| Three Phase, 230 V. (Min/Max Amps)3 | 137/186 | 135/184 | 183/254 | 183/254 | 281/352 | 197/273 | 313/389 |
| Three Phase, 460 V. (Min/Max Amps)3 | 71/93 | 70/92 | 94/127 | 99/132 | 143/176 | 101/139 | 159/197 |
| Three Phase, 575 V. (Min/Max Amps)3 | 65/82 | 68/86 | 78/105 | 82/109 | 115/142 | 85/117 | 128/160 |
3400 & 3600 Series
3400 Series: three modules, four fans and heaters, one on the upper and middle modules and two on the lower module. 3600 Series: three modules, six fans and heaters, two on each module. The maximum grain drying capacity in a Portable Dryer, for large farm operations.
| Model | 3414 | 3418 | 3420 | 3422 | 3426 | 3620 | 3626 |
|---|---|---|---|---|---|---|---|
| Dry & Cool 25% to 15% | 840 BPH | 1,040 BPH | 1,120 BPH | 1,250 BPH | 1,520 BPH | 1,120 BPH | 1,520 BPH |
| Dry & Cool 20% to 15% | 1,340 BPH | 1,670 BPH | 1,800 BPH | 2,020 BPH | 2,450 BPH | 1,800 BPH | 2,450 BPH |
| Full Heat 30% to 15%1 | 1,000 BPH | 1,250 BPH | 1,400 BPH | 1,510 BPH | 1,820 BPH | 1,400 BPH | 1,820 BPH |
| Full Heat 25% to 15%1 | 1,360 BPH | 1,680 BPH | 1,830 BPH | 2,040 BPH | 2,480 BPH | 1,830 BPH | 2,480 BPH |
| Full Heat 20% to 15%1 | 2,190 BPH | 2,720 BPH | 2,950 BPH6 | 3,300 BPH6 | 4,000 BPH6 | 2,950 BPH | 4,000 BPH |
| Basic Construction | 3 Modules/4 Stages | 3 Modules/4 Stages | 3 Modules/4 Stages | 3 Modules/4 Stages | 3 Modules/4 Stages | 3 Modules/6 Stages | 3 Modules/6 Stages |
| Grain Columns | 14″ x 14′ Long | 14″ x 18′ Long | 14″ x 20′ Long | 14″ x 22′ Long | 14″ x 26′ Long | 14″ x 20′ Long | 14″ x 26′ Long |
| Total Holding Capacity | 1,074 BU | 1,381 BU | 1,534 BU | 1,688 BU | 1,995 BU | 1,534 BU | 1,995 BU |
| Grain Column Holding Cap. | 1,022 BU | 1,314 BU | 1,460 BU | 1,606 BU | 1,898 BU | 1,460 BU | 1,898 BU |
| Top Auger (Loading) | 5 HP | 5 HP | 7.5 HP | 7.5 HP | 10 HP | 7.5 HP | 10 HP |
| Capacity | 3,800 BPH | 3,800 BPH | 3,800 BPH | 3,800 BPH | 3,800 BPH | 3,800 BPH | 3,800 BPH |
| Bottom Auger (Unloading) | 8″ Flight / 10″ Tube – 5 HP | 8″ Flight / 10″ Tube – 5 HP | 8″ Flight / 10″ Tube – 7.5 HP | 8″ Flight / 10″ Tube – 7.5 HP | 8″ Flight / 10″ Tube – 10 HP | 8″ Flight/10″ Tube – 7.5 HP | 8″ Flight/10″ Tube – 10 HP |
| Meter Roll Drive | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP | VFD, 1 HP |
| Maximum Capacity | 1,960 BPH | 2,520 BPH | 2,800 BPH | 3,080 BPH | 3,640 BPH | 2,800 BPH | 3,640 BPH |
| Transport Length (Hitch to Discharge Auger) | 23’2″ | 27’2″ | 29’2″ | 31’2″ | 35’2″ | 29’2″ | 35’2″ |
| Transport Width | 8′ | 8′ | 8′ | 8′ | 8′ | 8′ | 8′ |
| Transport Height2 | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) | 13’5″ (11’9″) |
| Approx. Transport Weight (Less Transport Kit) | 23,000 lbs. | 26,500 lbs. | 29,500 lbs. | 30,500 lbs. | 35,000 lbs. | 30,170 lbs. | 38,750 lbs. |
| Installed Length | 23’10” | 27’10” | 29’10” | 31’10” | 35’10” | 29’10” | 35’10” |
| Installed Width | 8’8″ | 8’8″ | 8’8″ | 8’8″ | 8’8″ | 8’8″ | 8’8″ |
| Installed Height (Excluding Foundation Supports) | 37’3″ | 37’3″ | 37’3″ | 37’3″ | 37’3″ | 37’3″ | 37’3″ |
| Top Heaters (Max BTU) | 2@5.5 Mil. btu/hr | 2@6.75 Mil. btu/hr | 2@7.5 Mil. btu/hr | 2@8.75 Mil. btu/hr | 2@10.25 Mil. btu/hr | 3@4.5 Mil. btu/hr | 3@6.75 Mil. btu/hr |
| Bottom Heaters (Max BTU) | 2@3 Mil. btu/hr | 2@3.5 Mil. btu/hr | 2@4.5 Mil. btu/hr | 2@4.5 Mil. btu/hr | 2@6.75 Mil. btu/hr | 3@4.5 Mil. btu/hr | 3@6.75 Mil. btu/hr |
| Top Fans 1 PH | 2@15 HP, 40″ | N/A | N/A | N/A | N/A | N/A | N/A |
| Bottom Fans 1 PH | 2@12 HP, 28″ | N/A | N/A | N/A | N/A | N/A | N/A |
| Top Fans 3 PH | 2@15 HP, 40″ | 2@20 HP, 42″ | 2@25 HP, 42″ | 2@30 HP, 42″ | 2@40 HP, 42″ | 3@15 HP, 36″ | 3@25 HP, 40″ |
| Bottom Fans 3 PH | 2@12 HP, 28″ | 2@10-12 HP, 36″ | 2@15 HP, 36″ | 2@15 HP, 36″ | 2@25 HP, 40″ | 3@15 HP, 36″ | 3@25 HP, 40″ |
| Single Phase, 230 V. (Min/Max Amps)3 | 303/358 | N/A | N/A | N/A | N/A | N/A | N/A |
| Three Phase, 208 V. (Min/Max Amps)3 | 188/238 | 210/260 | 266/343 | 266/343 | 300/377 | 295/377 | 539/620 |
| Three Phase, 230 V. (Min/Max Amps)3 | 175/224 | 183/232 | 245/316 | 245/316 | 279/350 | 273/349 | 441/517 |
| Three Phase, 460 V. (Min/Max Amps)3 | 90/112 | 94/116 | 125/158 | 135/168 | 192/225 | 139/177 | 223/261 |
| Three Phase, 575 V. (Min/Max Amps)3 | 81/98 | 88/106 | 103/130 | 111/138 | 154/181 | 117/149 | 179/211 |
X-Stream Series
Configuration: various. X-Stream is an optional rearrangement of the fans on 1200H, 1200S, 2300, 2400, 3400 or 3600 Series dryers, for any size farm that wants to dry grain more evenly.
| Models | 1220SX & 1220HX † | 1222SX & 1222HX † | 1226SX & 1226HX † | 2320X | 2322X | 2326X | 2420X | 2426X | 3420X | 3422X | 3426X | 3620X | 3626X |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Modules | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 3 | 3 |
| Fans | 2 | 2 | 2 | 3 | 3 | 3 | 4 | 4 | 4 | 4 | 4 | 6 | 6 |
| Phase | 1 or 3 | 1 or 3 | 3 | 3 | 3 | 3 | 1 or 3 | 3 | 3 | 3 | 3 | 1 or 3 | 3 |
| Voltage | ALL | ALL | ALL | ALL | ALL | ALL | ALL | ALL | ALL | ALL | ALL | ALL | ALL |
| Fuel | LP or NG | LP or NG | LP or NG | LP or NG | LP or NG | LP or NG | LP or NG | LP or NG | LP or NG | LP or NG | LP or NG | LP or NG | LP or NG |
| Weight (lbs.) | 14,500 | 15,500 | 18,500 | 21,000 | 22,500 | 25,000 | 24,100 | 28,600 | 29,500 | 30,500 | 35,000 | 31,000 | 39,600 |
| Full Heat (BPH) 10 pt. 25-15% | 615 | 670 | 820 | 1,245 | 1,355 | 1,670 | 1,250 | 1,670 | 1,825 | 2,040 | 2,475 | 1,830 | 2,480 |
| Full Heat (BPH) 5 pt. 20-15% | 990 | 1,080 | 1,330 | 2,010 | 2,195 | 2,700 | 2,010 | 2,700 | 2,9506 | 3,3006 | 4,0006 | 2,9506 | 4,0006 |
| Dry & Cool (BPH) 10 pt. 25-15% | 280 | 300 | 375 | 850 | 930 | 1,130 | 850 | 1,130 | 1,120 | 1,250 | 1,520 | 1,120 | 1,520 |
| Dry & Cool (BPH) 5 pt. 20-15% | 445 | 485 | 600 | 1,375 | 1,500 | 1,835 | 1,380 | 1,840 | 1,800 | 2,015 | 2,445 | 1,800 | 2,020 |
Drying capacities listed are wet bushels, for mature unfrozen #2 yellow shelled dent corn at listed moisture content and are estimates based on drying principles, field results and computer simulation. Variance may occur due to grain’s physiological factors (kernel size, chemical composition, variety, maturity), excessive fines, adverse weather conditions, etc.
1 - Grain discharged hot from the dryer will result in a final moisture content of 15% after cooling in the bin.
2 - Shortest possible height in ( ).
3 - Electric Load (Fan, Load Auger, Unload Auger) Minimum: Fan(s) & Dryer Load & Unload motor name plate amperages + 5 for control & VFD load. Maximum: Fan(s) & Dryer Load & Unload & largest auxiliary motor name plate amperages + 5 for control & VFD load.
4 - Small Grain Screen Perforations (O.055”) are available for canola and other small grains. There will be an approximate 20% reduction in capacity on corn and other large grains.
5 - Single to three phase converters can be used.
6 - Limited by Meter Roll maximum capacity.
† - S-Series dryers are upgradable with additional modules, while the H-Series is not.